FYRA Vacuum Controller - Multi-Gauge Controller with Touchscreen - ATM to High Vacuum - UL/CSA/CE

Previous 4 / 6 Next

FYRA Vacuum Controller - Multi-Gauge Controller with Touchscreen - ATM to High Vacuum - UL/CSA/CE DigiVac StrataVac Controllers Vacuum Measurements


FYRA Vacuum Gauge Controller – DigiVac’s Latest Innovation
UL Certified FYRA Vacuum Gauge Controller now with support of convection-enhanced pirani sensors.
The DigiVac FYRA vacuum gauge controller is a digital vacuum control instrument that is highly configurable and capable of driving multiple types of sensors (piezo, thermal, active, passive, and capacitance manometers). It employs a 3.9” capacitive touch screen and includes a tactile knob to easily interact with the vacuum gauge functions. FYRA can intuitively display and manage multiple sensors and control points.
Vacuum Science Simplified
We know vacuum applications can get complicated. FYRA was created to deliver scientific measurement and vacuum control simply with easy integration into almost any system in the market.
The Power of 4
FYRA gives you the essence of versatility with a touchscreen or dial interface and ability to measure and control from atmosphere to high vacuum range. Based on sensor choice, Ability to support measurement and control range of 10-10 Torr – 1000 Torr.
FYRA Display
Three Variations on how to integrate Fyra into your lab space: Bench Top, Panel Mount and Rack Mount are available.
Example of a FYRA Application
Imagine a vacuum system that is controlled by a PLC, where the PLC sends an analog signal corresponding to a vacuum pressure level to be maintained. Meanwhile, the FYRA sends back current vacuum pressure to the PLC.
In this application example, the other pieces of equipment would operate as follows (slots refer to back panel image):
Dinamo Valve
The pressure can be maintained by the DigiVac Dinamo Valve. (Slot B)

Capacitance Manometer
1000 Torr capacitance manometer would be the sensor to
be used for the control of vacuum pressure. (Slot D)

531 Sensor
The 531 sensor is used at the inlet of the vacuum pump to monitor inlet pressure. (Slot C)

Convectron
The convectron is put on the chamber in order to see the wide range base pressure of the system chamber. (Slot A)

VacStable
The VacStable is used to sweep a specific amount of gas (sccm) through the chamber. (Slot F)

WiFi Connection
View pressure in real time through vacuumnetwork.org, and log data through the USB interface.

About Panel/Rack Mount
The Panel mount kit for the Fyra vacuum controller allows easy panel mounting; 2U 19” rackmount kit for mounting 2 Fyra Scientific controllers in an industry standard 19 inch rack
  • Transforms the Fyra table top Vacuum controller into a rack mounted vacuum controller
  • 19” rack mount enables  2 Fyra vacuum controllers to be mounted in only 2U of space in a 19” rack
  • Ideal for permanent installation of DigiVac scientific controls
Rack-Mount Features
  • A large flange that allows easy cutting and mounting of the Fyra into an panel
  • Beveled around display to improve viewing angle
  • A rackmount kit to enable simple mounting of up to two Fyra controllers into industry standard 19 inch racks.
Rack Mount Applications
For customer or OEM integration into equipment solutions requiring vacuum measurement and control.
Examples
  • A research lab that wants to integrate easy to use modern vacuum controls and displays in their research system(s)
  • A manufacturer that want to use
Compatible Sensors:
Sensors supported include:  
Inficon MPG400/401
PSG5xx ATM to Medium Vacuum Gauge
Gemini MAG500 Cold Cathode
Gemini MPG500 Cold Cathode Pirani
PCG550
Porter
SKY
Stripe
MAG
MKS AA01, 722B, 730B
Convection: 27571 (1/8″ NPT), 275203 (KF16)
KJLC KJLC Pirani
KJLC Cold Cathode
KJLC Cold Cahtode Pirani
AGC 0.1 T CM
AGC 0.5 T CM
AGC 1 T CM
AGC 5 T CM
AGC 10 T CM
AGC 20 T CM
AGC 50 T CM
AGC 100 T CM
AGC 1000 T CM
Agilent PVG-500
PVG-550
IKR251
FRG-700
FRG-720
PCG-750
PCG-700

536
531
CDG500 1 T CM
CDG500 10 T CM
CDG500 100 T CM
CDG500 1000 T CM
Edwards ASG2, APG200-XM, WRG200
DigiVac SEN-VGT500
SEN-775i
Quantum (SEN-DPP, SEN-DCP, SEN-DPCP)
Pfieffer PKR251
IKR251
Leybold Ceravac: 1, 10, 100, 1000T CM
Thermovac: TTR 91, TTR 96, TTR 97, TTR 101, TTR 200N
Sentra 730 capacitance manometers
 
Technical Specifications
Units Torr, mbar, kPa, Pa, microns (choose mTorr), millitorr (mTorr), mmHg, Hectopascal
Control Range Ability to support 10-10 Torr – 1000 Torr
Dimensions 6.5″x6.5″x2.5″
Telemetry Options USB, WiFi, 0-10 volts DC, Analog out, 0-10 volts DC Analog in
Sensor Support MKS Convectron: 275071 (1/8″ NPT), 275203 (KF16);   DigiVac: SEN-VGT500, SEN-775i, Quantum (SEN-DPP, SEN-DCP, SEN-DPCP);  Pfeiffer: PKR251, IKR251;   Agilent: FRG700, PCG-750, PCG700, 531, 536, 531 equivalent, or PVG 500;   Setra: 730 capacitance manometers;   Inficon: PSG500, PSG550, Porter, SKY, Stripe, MAG, MPG & MPG400
Valve Support Dinamo, VacStable (Bleed), Solenoid-type Bellows and Plunger, 24V valves that are less than 24 Watts




 